WXF high temperature motor has the ability to withstand high temperature fire test, meets S1 and S2 operating conditions: under normal circumstances can be used as general motor , long-term continuous operation; In case of emergency smoke and smoke exhaust, starts S2 short-time operation. If the ambient temperature is up to 400ºC, reliable operation for 2 hours, in line with the emergency working conditions of high temperature fire motor.
This series of motors has the characteristics of low loss, low vibration, safety and reliability, easy maintenance and so on.
Implementation standards
WXF high temperature motor is an energy efficiency upgrade product independently developed by our company. Its efficiency meets the IEC60034-30-1 IE4 and IE2 efficiency standards. Installation dimensions conform to IEC standards.
Operating condition
Normal temperature
Ambient air temperature:-20℃~+40℃;
Altitude: ≤1000m;
Note:When the ambient air temperature, altitude and the above provisions do not at the same time according to the provisions of GB755;
Humidity: monthly average maximum relative humidity does not exceed 90%.
Parameter
Mounting